// NETA acceptance & maintenance testing
Field-first test management for NETA shops - spec-accurate forms, same-day sealed reports, and full offline capture in the substation. Form authoring is free on every plan.
Form authoring included on every plan. No desktop designer license, no per-copy fees.
// 01 - the difference
Legacy desktop tools tie form authoring to a paid Windows license and a desktop designer, so most shops wait on the one person who has it. In Verlecta, a senior tech clones a NETA form, edits a field, and publishes - in minutes, in the browser, with full versioning and an audit trail. That capability is never paywalled.
Fork any catalog form, change labels, units, and tolerances, and ship it. No pixel-positioning, no formula-language gymnastics.
Every change is tracked to the user who made it. Sealed results stay pinned to the exact form version they were taken against.
Clone and fork for a customer-specific variant. No sync-system lock-in.
// 02 - built for the field
Substations and underground vaults have no signal. Verlecta caches your jobs, captures results and signatures offline, and syncs the moment you reconnect.
Visual & mechanical inspection first, then electrical tests in the standard’s sequence, with tolerances shown at the point of entry - pass/fail as you type.
A PE seals and the customer-ready PDF generates immediately. Real-time delivery is the moat - the report goes out the same day, not after a slow office round-trip.
Instrument calibration is tracked on every report - calibration certificates recorded and printed on the report, with 12-month due warnings baked in.
Hands busy, eyes on the equipment: the app announces each field, you speak the reading, it reads the value back, and nothing is saved until you confirm. English and Spanish first; French is in testing.
Load the export file from your test set, map its columns to the form once, and the mapping is remembered for that instrument model. Imported values are graded exactly like typed ones and remember the file they came from. Generic CSV today.
// 03 - for your customers
Invite a customer contact and they sign in with a link sent to their email, no password. They see only their own sites, equipment and what is due, every sealed report and the open items, under your logo and color, in English, Spanish or Canadian French. Read-only, and you revoke access from the same page.
One action on a job or a customer builds a ZIP: the asset list, one row per test with its verdict, every sealed report PDF and a manifest with a checksum for each file, plus work-order and checklist sheets as flat sheets laid out for import into maintenance and commissioning platforms. Files only; nothing is sent anywhere.
// 04 - the honest comparison
PowerDB is a trademark of Megger. Comparison reflects publicly reported tiering; verify current pricing with the vendor.
// 05 - traceable to the standard
Verlecta’s form library is authored from the published NETA acceptance and commissioning specifications and the underlying ASTM and IEEE test methods - with documented provenance for every form, built field by field from the spec. The library rests on more than 30 owned standards documents that we digest or index and watch for revisions.
Under the help for a field, where a free United States government document describes the same practice as the standard the field cites, the Reference line names it and opens the passage itself, word for word with its date. Twelve public documents and 1,517 reviewed passages today; nothing is graded differently.
Maintenance due dates follow the NFPA 70B-2026 electrical testing intervals by asset type and condition, with each asset rated on physical condition, criticality and operating environment and the overall condition set by the worst of the three.
How traceability works →
// 06 - UltraDb Original forms
Some acceptance work has no published ANSI/NETA section to build from: equipment sections the acceptance standard leaves reserved, and tests that an IEEE or ANSI document defines and the neighboring section does not carry. For those, UltraDb authors its own Original forms on the standards that govern the equipment, with every line citing its source and no acceptance value invented where a standard gives none. In the catalog today: 21. In review: 0. In development: 0.
Stands beside ANSI/NETA ATS-2025 7.27, which the acceptance standard leaves reserved
Stands beside ANSI/NETA ATS-2025 7.12.2, which the acceptance standard leaves reserved
Stands beside ANSI/NETA ATS-2025 7.10.4, which the acceptance standard leaves reserved
Stands beside ANSI/NETA ATS-2025 7.18.3, which the acceptance standard leaves reserved
Stands beside ANSI/NETA ATS-2025 7.30, which the acceptance standard leaves reserved
Stands beside ANSI/NETA ATS-2025 7.3.1, which the acceptance standard leaves reserved